Xantrex Technology Thermostat 2000 R User Manual

 
Regulator Troubleshooting Flow Chart  
Most regulation problems can be solved with the following flow chart  
Terminals #1 through #10 are on the Monitor Terminal Board.  
Wires referred to by color are in the wiring harness for the Ideal Regulator Output Module  
NO OUTPUT  
Check  
Do final progress  
& startup test  
described on page 14  
No or variable  
alternator current  
OK  
alternatorbelts, field  
wire,alternator  
ground, & field gnd.  
FAIL TEST  
HIGH VOLTAGE  
Is the Red CHG  
LED on the Output  
Module lit?  
Is the green ON LED  
Voltage OK, problem  
in alternator. If not  
OK, problem in wire  
or connections.  
Is the wiring harness  
from the Output  
Module pluged in  
correctly  
Check for voltage at  
the alternator end of  
the blue field wire.  
Should be 10 to 12V.  
HIGH VOLTAGE,  
REGULATOR NOT  
IN CONTROL.  
YES  
YES  
YES  
YES  
located on the  
Output Module lit?  
NO  
NO  
Is there 12V between  
the black wire and  
the brown wire REG  
ON?  
With engine off  
Is there 12V between  
black & red wires, if  
not check fuse  
Alternator shunt sense  
leadsreversedand  
current > 100.  
Is the Charge Cycle  
status light lit on the  
front panel of the  
meter?  
LIT  
make sure the  
Green LED REG  
ON is not lit.  
supplying red wire  
Reversesenseleads.  
NO  
NO  
NOT LIT  
Is the oil pressure  
switch jumpered or  
the key turned on?  
Is phone cord between  
Monitor Board and  
Output Module  
Output Module is  
bad. Replace it.  
Is the Red CHG LED  
Output Module lit?  
Disconnect the  
brown REG ON  
wire, is the RED  
LED still lit?  
YES  
YES  
pluggedincorrectly?  
NO  
NO  
YES  
Be sure set up correct  
for your battery  
Is there about 5V  
between term #1 and  
the test point shown  
on the Monitor TB?  
Problem in ribbon  
cable or meter. Try re-  
pluggingcable  
The problem is in  
the alternator or the  
externalwiring.  
Checkcircuit  
supplying the switch  
(fuse & wire).  
YES  
system. Is Bat#2  
defeated?Seemanual.  
If not OK call us.  
NO  
Is there about 5V  
between term #1 and  
the test point shown?  
If voltage is OK  
problem is with  
Monitor Terminal  
board, replace it.  
Check battery voltage  
sense leads. Do  
YES  
Use this flow chart to assist in troubleshooting if  
progress test #1.  
you encounter unexpected results during installa-  
tion, start up, and operation of your new LINK  
2000-R  
NO  
If alternator was  
converted from  
internal reg. was  
diode trio removed?  
If there is no voltage  
the problem is in the  
phone cord or  
connections.  
 
 
 
 
 
 
 
 

Weider Home Gym WESY85201 User Manual
Weslo Treadmill WETL268060 User Manual
Whirlpool Freezer EH120F User Manual
Whirlpool Microwave Oven GH7145XF User Manual
Whirlpool Microwave Oven GT4175SPB0 User Manual
White Rodgers Stud Sensor F145 0825 User Manual
Yamaha DVD Recorder DRC 20 User Manual
Zanussi Oven ZOB 641 User Manual
Zanussi Refrigerator 12R Z21 User Manual
Zanussi Refrigerator ZU 8124 User Manual